Heat Controller Universal Remote R51L10 BGCE User Manual

REMOTE CONTROLLER  
OWNER’S MANUAL  
B-SMA/SMH09/12/18SC  
Single Zone Mini-Splits  
B-VMH09/12/18/24/30/36SC-1  
Single Zone Inverter Mini-Splits  
B-VMH09/12/18FC-1  
Multi-Flex Inverter Mini-Splits  
Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com  
 
Heat Controller, Inc.  
Remote ContRolleR  
Owner’s Manual  
Using the Remote Controller  
Use the remote controller within a distance of 26' 3"  
(8 meters) from the appliance, pointing it towards the  
receiver. Reception is confirmed by a beep.  
receiver  
housing  
Remove the battery cover by pressing and sliding it off.  
2
 
Owner’s Manual  
Remote ContRolleR  
Heat Controller, Inc.  
an extended period of time.  
Remote Controller Specifications  
R51l5BG(C)E, R51l6/BG(C)E,  
R51l7/BG(C)E, R51l8/BG(C)E, R51l9/BG(C)E;  
R51l10/BG(C)E, R51l11/BG(C)E, R51l12/BG(C)E;  
Model*  
Rated Voltage  
3.0V (Dry batteries R03/LR03x2 or (2) AAA)  
Lowest Voltage of CPU Emitting Signal  
Signal Receiving Range  
Environment  
2.0V  
26'3" (8m)  
-41°F~140°F (-5°C~60°C)  
*NOTE:  
Temperature setting display:  
Fahrenheit scale (°F): R51l9/BG(C)E; R51l10/BG(C)E, R51l11/BG(C)E, R51l12/BG(C)E  
Celsius scale (°C): R51l5BG(C)E, R51l6/BG(C)E, R51l7/BG(C)E, R51l8/BG(C)E  
Performance Feature  
Indoor setting temperature range: 62°F~88°F (17°C~30°C)  
Full function of LCD Display (Liquid Crystal Display)  
3
 
Heat Controller, Inc.  
Remote ContRolleR  
Owner’s Manual  
Function Buttons  
AUTO  
COOL  
DRY  
HEAT*  
FAN  
*NOTE: Heat pump models only  
ION and FOLLOW buttons  
are optional functions.  
4
 
Owner’s Manual  
Remote ContRolleR  
Heat Controller, Inc.  
Function Buttons (continued)  
ECONOMY Button (Sleep Mode)  
to maintain the most comfortable temperature  
TIMER OFF Button  
ION and FOLLOW buttons  
are optional functions.  
Press this recessed button to lock all current set-  
tings. Use the LOCK mode when you want to  
prevent settings from being changed accidentally.  
Press the LOCK button again to cancel the LOCK  
function. A key symbol will appear on the remote  
controller display when the lock function is activated.  
5
 
Heat Controller, Inc.  
Remote ContRolleR  
Owner’s Manual  
Indicators on LCD Display  
The temperature setting (from 62°F (17°C)  
to 88°F (30°C)) or timer setting (0~24h)  
will be displayed. If FAN mode is selected,  
there will be no display.  
A key symbol is displayed when pushing  
the LOCK button. Push the LOCK button  
to clear display.  
6
 
Owner’s Manual  
REMOTE CONTROLLER  
Heat Controller, Inc.  
How to use the buttons  
Auto operation  
Ensure power is available to the unit. The OPERATION  
indicator on the display panel of the indoor unit illumi-  
nates.  
1. Press the MODE button to select Auto.  
2. Press the TEMP button to set the desired tempera-  
ture. The temperature can be set within a range of  
62°F (17°C)~88°F (30°C) in 2°F (1°C) increments.  
3. Press the ON/OFF button to start the air conditioner.  
2
1
3
NOTE  
1. In the Auto mode, the air conditioner can logically choose the  
mode of Cooling, Fan, Heating and Dehumidifying by sens-  
ing the difference between the actual ambient room temper-  
ature and the set temperature on the remote controller.  
2. In the Auto mode, you can not switch the fan speed. It is  
automatically controlled in this mode.  
3. If the Auto mode is not comfortable for you, the desired  
mode can be selected manually.  
Cooling/Heating/Fan Operation  
Ensure power is available to the unit.  
1. Press the MODE button to select COOL, HEAT (cool-  
ing & heating models only), or FAN mode.  
2. Press the TEMP button to set the desired tempera-  
ture. The temperature can be set with a rnage of 62°F  
(17°C)~88°F (30°C) in 2°F (1°C) increments.  
3. Press the FAN SPEED button to select the fan speed  
in four steps–Auto, Low, Med or High.  
2
1
4
4. Press the ON/OFF button to start the air conditioner.  
3
NOTE  
In the FAN mode, the setting temperature is not displayed  
in the remote controller. In fan only mode, the fan creates a  
breeze without cooling or heating the room. To cool or heat  
the room, cooling or heating modes need to be selected  
rather than fan only.  
7
 
Heat Controller, Inc.  
REMOTE CONTROLLER  
Owner’s Manual  
Dehumidifying operation  
Ensure power is available to the unit. The OPERATION  
indicator on the display panel of the indoor unit illumi-  
nates.  
1. Press the MODE button to select DRY mode.  
2. Press the TEMP button to set the desired tempera-  
ture. The temperature can be set within a range of  
62°F (17°C)~88°F (30°C) in 2°F (1°C) increments.  
3. Press the ON/OFF button to start the air conditioner.  
NOTE  
2
1
3
In the Dehumidifying mode, you can not switch the fan  
speed as it is being automatically controlled.  
Swing operation  
direction.  
direction setting feature of the louver is activated. The  
angle of the louver changes by 6° each time the but-  
ton is pressed. Keep pressing the button to move the  
louver to the desired position.  
2. By pressing the SWING button without releasing it for  
2 seconds, the auto swing feature of the louver acti-  
vates. The horizontal louver swings up/down automati-  
cally. Press it again to stop.  
1
NOTE  
When the louver moves to a position which would affect the  
cooling and heating effect of the air conditioner, it will auto-  
matically change the swing/louver direction.  
8
 
Owner’s Manual  
Remote ContRolleR  
Heat Controller, Inc.  
Pressing the TIMER ON button can set the auto-on  
time of the unit. And pressing the TIMER OFF button  
can set the auto-off time of the unit.  
symbol  
.
SEE NOTE.  
symbol  
SEE NOTE ON NEXT PAGE.  
symbol  
9
 
Heat Controller, Inc.  
Remote ContRolleR  
Owner’s Manual  
10  
 
Owner’s Manual  
Remote ContRolleR  
Heat Controller, Inc.  
symbol “h” will  
11  
 
Heat Controller, Inc.  
REMOTE CONTROLLER  
Owner’s Manual  
ECONOMY (SLEEP MODE) operation  
When you press the ECONOMY button, the econ-  
omy/sleep mode running function will be activated,  
the set temperature will increase (in cooling) or  
decrease (in heating mode) by 2°F (1°C) over the  
next 30 minutes and by another 2°F (1°C) after an  
additional 30 minutes. This new temperature will  
be maintained for 7 hours before it returns to the  
originally selected temperature. (NOTE: On some  
models, the set temperature will increase (cooling)  
or decrease (heating) by 2°F (1°C) per hour for 2  
hours. This new temperature will be maintained for 5  
hours, then the unit turns off.)  
NOTE: The ECONOMY/SLEEP function is only  
available under Cooling, Heating and Auto  
operation.  
12  
 
10/2012  
 

Graco Mixer 309535L User Manual
Grizzly Saw G0734 User Manual
Grizzly Saw G1010 User Manual
Hamilton Beach Blender 840120300 User Manual
Hasbro Games Trickster Game User Manual
Hasselblad Film Camera 10026 User Manual
Heat Glo LifeStyle Indoor Fireplace 6000GLX IPILP S R User Manual
Heatiator Indoor Fireplace GC150 User Manual
Hotpoint Ventilation Hood LI2SNA User Manual
HP Hewlett Packard Projector mp3222 User Manual